- Cement resistor is a product that combined with 10W wire wound resistor (ceramics insulator) type.
- 10K is RoHS compliance product, non-Pb and non-Cd contains.
- Especially, 10K adopted excellent characteristic resistive element against the In-rush current, and it is the best for preventing In-rush current.
- In-rush Resistance Characteristics


Dimension
| A | 7.5±0.5 |
| B | 3.5+1、-0.5 |
| C | 34±0.5 |
| D | 17.5±0.5 |
| E | 11±0.5 |
| F | Φ0.80±0.04 |
| G | Φ0.80±0.04 |
Construction
| Ceramic case | |
| Silicone cement | |
| Resistance (Ceramic insulator) |
|
| Lead wire (Tin plated copper wire) |
Models Component

Ratings
| Model name | 10K JA |
| Rated power(25°C) | 10.0W |
| Nominal resistance value | 1.8~1kΩ※1 |
| Resistance tolerance | ±5% |
※
Derating Curve

Performance standard
The following qualities will be examined, and we be offering the product that past a safety standard.Resistance value
- Specifications
- Resistance shall be within ±5% of nominal resistance value.
- Test Methods
- The following DC voltage is applied across lead terminals for measurements.
| Nominal resistance range[Ω] | Max. applied Volt.[V] | |
|---|---|---|
| 1 and over | less than 10 | 0.3 |
| 10 and over | less than 100 | 1 |
Insulation resistance
- Specifications
- Between body and lead terminals
Insulation resistance shall be 1000MΩ or above. - Test Methods
| Between body and lead terminals | DC500V is impressed and measured between metallic foil wrapped on the case, and lead terminals. |
|---|
Dielectric strength
- Specifications
- Between body and lead terminals
The products shall withstand for 1minute. - Test Methods
| Between body and lead terminals | AC1.5kV is impressed for 1 minute and measured between metallic foil wrapped on the case, and lead terminals. (Cutoff current 0.5mA) |
|---|
Temperature coefficient of resistance
- Specifications
- ±250ppm/°C
- Test Methods
- Room temperature/70°C up
Short time overload
- Specifications
- ±(2%+0.05Ω)
- Test Methods
- Rated power×10, for 5 sec.
Terminal strength
- Specifications
- No mechanical damages
- Test Methods
- Pull 20N, 1 min
Bending 90°C 1 cycle
Humidity resistance
- Specifications
- ±(2%+0.05Ω)
- Test Methods
- 40°C, Humidity 90~95%RH, 10000h
Load life
- Specifications
- ±(3%+0.05Ω)
- Test Methods
- Rating load 1000h, 1.5h ON/0.5h OFF cycle

JA